OUTPUT |
Output Volt Amp Capacity (VA) | 2200 | Output kVA Capacity (kVA) | 2.2 | Output Watt Capacity (Watts) | 1600 | Output kW Capacity (kW) | 1.6 | Power Factor | 0.7 | Nominal Output Voltage(s) Supported | 220V; 230V; 240V | Nominal Voltage Details | 230v inverter nominal output voltage | Frequency Compatibility | 50 / 60 Hz | Output Voltage Regulation (Line Mode) | -19% +8% | Output Voltage Regulation (Battery Mode) | +/- 5% | Output Receptacles | (8) C13; (1) C19 | Included Output Power Cables | Includes 3 C13 to C14 output power cables | Load Management Receptacles | Three switchable two-outlet C13 load banks | Output Circuit Breakers | 10A (x2) – each breaker protects 4 C13 outlets each, C19 is unbreakered | Hot-Swap PDU options | PDUBHV20 (2U / 6 C13, 2 C19 outlets) | Output AC Waveform (AC Mode) | Sine wave | Output AC Waveform (Battery Mode) | PWM sine wave |
|
INPUT |
Rated input current (Maximum Load) | 11.3A | Nominal Input Voltage(s) Supported | 230V AC | UPS Input Connection Type | C20 inlet | UPS Input Connection Description | IEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles | Input Phase | Single-Phase |
|
BATTERY |
Full Load Runtime (min.) | 7 min. (1600w) | Half Load Runtime (min.) | 19 min. (800w) | DC System Voltage (VDC) | 48 | Battery Recharge Rate (Included Batteries) | Less than 4 hours from 10% to 90% (typical, full load discharge) | Internal UPS Replacement Battery Cartridge | RBC54 | Battery Access | Provides the battery access door | Battery Replacement Description | Hot-swappable, user replaceable batteries | Expandable Runtime | No |
|
VOLTAGE REGULATION |
Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 282V | Overvoltage Correction | Input voltages between 245 and 282 are reduced by 12% | Undervoltage Correction | Input voltages between 177 and 199 are boosted by 14% | Severe Undervoltage Correction | Input voltages between 151 and 176 are boosted by 30% |
|
USER INTERFACE, ALERTS & CONTROLS |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation | Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status | Audible Alarm | Audible alarm indicates power-failure, overload and low-battery conditions | LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
|
SURGE / NOISE SUPPRESSION |
UPS AC Suppression Joule Rating | 480 | UPS AC Suppression Response Time | Instantaneous | EMI / RFI AC Noise Suppression | Yes |
|
PHYSICAL |
Primary Form Factor | Tower | UPS Power Module Dimensions (hwd, cm) | 36.2 x 23.5 x 30.5 | UPS Power Module Weight (kg) | 24.5 | UPS Shipping Dimensions (hwd / cm) | 40.6 x 37.5 x 50.2 | Shipping Weight (kg) | 27.5 | Cooling Method | Fan | UPS Housing Material | Polycarbonate |
|
ENVIRONMENTAL |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius | Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius | Relative Humidity | 0 to 95%, non-condensing | AC Mode BTU / Hr. (Full Load) | 347.2 | Battery Mode BTU / Hr. (Full Load) | 812.9 | AC Mode Efficiency Rating (100% Load) | 94% | Audible Noise | Audible Noise < 47dBA At Front Side 1 Meter |
|
COMMUNICATIONS |
Communications Interface | USB; DB9 Serial; Contact closure | Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions; 2 USB ports, 1 DB9 serial and 1 DB9 contact closure port (4 total) | PowerAlert Software | Included | Communications Cable | 2 USB and 2 DB9 cables included | WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
LINE / BATTERY TRANSFER |
Transfer Time | 2-4 milliseconds | Low Voltage Transfer to Battery Power (Setpoint) | 151 | High Voltage Transfer to Battery Power (Setpoint) | 282 |
|
SPECIAL FEATURES |
Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported | High Availability UPS Features | Hot swappable batteries | Green Energy-Saving Features | Individually controllable load banks |
|
CERTIFICATIONS |
UPS Certifications | CE; Meets FCC Part 15 Category A (EMI) | UPS Certification Details | CE 62040 |
|
WARRANTY |
Product Warranty Period (International) | 2-year limited warranty | Product Warranty Period (Mexico) | 2-year limited warranty | Product Warranty Period (Puerto Rico) | 2-year limited warranty |
|