+971-4-3559507            +971-558663158               info@netmateit.com

Shopping cart
AED0.00

SU100KX2

In stock

Categories: ,

Description

SU100KX2

We give the best SU100KX2 price in Dubai. In addition to this we are the best tripp lite distributors in Dubai. More than this we are the best tripp lite SU100KX2 product suppliers in Dubai. More than this we give the best tripp lite product support services in Dubai.

OUTPUT
Output Volt Amp Capacity (VA) 100000
Output kVA Capacity (kVA) 100
Output Watt Capacity (Watts) 80000
Output kW Capacity (kW) 80
Output Capacity Details One open power module slot enables installation of up to one additional 20kVA power module for increased capacity to 120kVA (authorized technician required)
Power Factor 0.8
Crest Factor 3:1
Nominal Output Voltage(s) Supported 220/380V; 230/400V; 240/415V; 3-Phase Wye
Nominal Voltage Details Less than 3% output THD
Frequency Compatibility 50 / 60 Hz
Output Voltage Regulation (Line Mode) +/- 1%
Output Voltage Regulation (Battery Mode) +/- 1%
Output Receptacles Hardwire
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
INPUT
Rated input current (Maximum Load) 129A (220/380), 123A (230/400), 116A (240/415)
Nominal Input Voltage(s) Supported 220/380V (3ph wye); 230/400V (3ph wye); 240/415V (3ph wye)
Nominal Input Voltage Description 3-Phase Wye, 4 wire (L1, L2, L3, N, G); Less than 4% input harmonic distortion (THDi)
UPS Input Connection Type Hardwire
Input Phase 3-Phase
BATTERY
Expandable Battery Runtime Battery set sold separate
External Battery Pack Compatibility BP480V200; BP480V300; BP480V400; BP480V500
Expandable Runtime Description External battery pack wiring is contractor supplied
DC System Voltage (VDC) +/- 240VDC
Battery Replacement Description Hot-swappable, replaceable batteries
Expandable Runtime Yes
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning
Overvoltage Correction Maintains continuous operation without using battery power during overvoltages to 276-477 (3-phase, 4-wire, wye), reducing output within 1% of nominal
Undervoltage Correction Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300 (3-phase, 4-wire, wye)
USER INTERFACE, ALERTS & CONTROLS
Switches ON button turns UPS inverter on. OFF button turns UPS inverter off. LCD Display Control Buttons browse through and select items displayed on LCD screen. EPO (Emergency Power Off) button turns UPS output off and disables Bypass output
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm Alarms signal a variety of operational conditions: low-battery, overload, shutdown, bypass and more
LED Indicators 4-LED Display: Displays normal AC input, on battery power, bypass input and fault conditions
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 5960
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Installation Form Factors Supported with Included Accessories Tower
Primary Form Factor Tower
UPS Power Module Dimensions (hwd, cm) 169.7 x 52.1 x 97.5
UPS Power Module Weight (kg) 347.5
UPS Shipping Dimensions (hwd / cm) 193.3 x 193.3 x 122.4
Shipping Weight (kg) 347.5
Cooling Method Fans
UPS Housing Material Steel
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 17400
COMMUNICATIONS
Communications Interface DB9 Serial; Slot for SNMP/Web interface
PowerAlert Software Included
Communications Cable DB9 cabling included
LINE / BATTERY TRANSFER
Transfer Time No transfer time (0 ms.) in online, double-conversion mode
Low Voltage Transfer to Battery Power (Setpoint) Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300V AC (3-phase, 4-wire, wye). Below this point, output is maintained utilizing reserve battery power
High Voltage Transfer to Battery Power (Setpoint) Maintains continuous operation without using battery power during overvoltages to 276-477V AC (3-phase, 4-wire, wye), reducing output within 1% of nominal. Above this point, output is maintained utilizing reserve battery power
SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Automatic inverter bypass; Hot swappable batteries
Green Energy-Saving Features High efficiency economy mode operation; Schedulable daily hours of economy mode operation
CERTIFICATIONS
UPS Certifications CE; ROHS (Restriction of Hazardous Substances)
WARRANTY
Product Warranty Period (International) 2-year limited warranty
Product Warranty Period (Mexico) 2-year limited warranty
Product Warranty Period (Puerto Rico) 2-year limited warranty

 

×