OUTPUT |
Output Volt Amp Capacity (VA) | 2000 | Output kVA Capacity (kVA) | 2 | Output Watt Capacity (Watts) | 1400 | Output kW Capacity (kW) | 1.4 | Power Factor | 0.7 | Crest Factor | 3:1 | Nominal Output Voltage(s) Supported | 220V; 230V; 240V | Nominal Voltage Details | 230V default | Frequency Compatibility | 50 / 60 Hz | Frequency Compatibility Details | Output frequency matches input nominal on startup, defaults to 50 Hz on cold-start | Output Voltage Regulation (Line Mode) | +/- 2% | Output Voltage Regulation (Economy Line Mode) | +/- 10% | Output Voltage Regulation (Battery Mode) | +/- 2% | Output Receptacles | (8) C13 | Included Output Power Cables | Includes 3 C13 to C14 output power cables | Hot-Swap PDU options | PDUBHV20 (2U / 6 C13, 2 C19 outlets) | Output AC Waveform (AC Mode) | Sine wave | Output AC Waveform (Battery Mode) | Pure Sine wave |
|
INPUT |
Rated input current (Maximum Load) | 7.4A (220V), 7.1A (230V), 6.8 (240V) | Nominal Input Voltage(s) Supported | 220V AC; 230V AC; 240V AC | UPS Input Connection Type | C20 inlet | UPS Input Connection Description | IEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles | Input Circuit Breakers | 20A | Input Phase | Single-Phase |
|
BATTERY |
Full Load Runtime (min.) | 5 min. (1400w) | Half Load Runtime (min.) | 14 min. (700w) | Expandable Battery Runtime | Extended runtime supported via optional external battery packs | External Battery Pack Compatibility | BP72V15-2U(limit 1); BP72V28RT-3U(multi-pack compatible) | DC System Voltage (VDC) | 72 | Battery Recharge Rate (Included Batteries) | Less than 4 hours from 10% to 90% (typical, full load discharge) | Battery Replacement Description | Hot-swappable, user replaceable batteries | Expandable Runtime | Yes |
|
VOLTAGE REGULATION |
Voltage Regulation Description | Online, double-conversion power conditioning | Overvoltage Correction | 2% output voltage regulation during overvoltages to 280 | Undervoltage Correction | 2% output voltage regulation during undervoltages to 175 | Severe Undervoltage Correction | 2% output voltage regulation during undervoltages to 80 (under 50% load only) |
|
USER INTERFACE, ALERTS & CONTROLS |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation | Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch | Audible Alarm | Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions | LED Indicators | 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information – includes 4-LED meter display for load and battery charge level |
|
SURGE / NOISE SUPPRESSION |
UPS AC Suppression Joule Rating | 570 | UPS AC Suppression Response Time | Instantaneous | EMI / RFI AC Noise Suppression | Yes |
|
PHYSICAL |
Primary Form Factor | Tower | UPS Power Module Dimensions (hwd, cm) | 37.3 x 14 x 42.4 | UPS Power Module Weight (kg) | 30.5 | UPS Shipping Dimensions (hwd / cm) | 49.3 x 24.9 x 60.5 | Shipping Weight (kg) | 33.5 | Cooling Method | Fan | UPS Housing Material | Steel |
|
ENVIRONMENTAL |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius | Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius | Relative Humidity | 0 to 95%, non-condensing | AC Mode BTU / Hr. (Full Load) | 528.9 | AC Economy Mode BTU / Hr. (Full Load) | 303.8 | Battery Mode BTU / Hr. (Full Load) | 774.9 | AC Mode Efficiency Rating (100% Load) | 90% | AC Economy Mode Efficiency Rating (100% Load) | 94% | Audible Noise | < 45 dB at front side 1m |
|
COMMUNICATIONS |
Communications Interface | DB9 Serial; Slot for SNMP/Web interface | Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 communications | PowerAlert Software | Included | Communications Cable | DB9 cabling included |
|
LINE / BATTERY TRANSFER |
Transfer Time | No transfer time (0 ms.) in online, double-conversion mode | Low Voltage Transfer to Battery Power (Setpoint) | 175V (100% load), 80V ( <50% load) | High Voltage Transfer to Battery Power (Setpoint) | 280 |
|
SPECIAL FEATURES |
Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported | High Availability UPS Features | Automatic inverter bypass |
|
CERTIFICATIONS |
UPS Certifications | CE | UPS Certification Details | CE EN62040-1-1, EN62040-2 Class A |
|
WARRANTY |
Product Warranty Period (Worldwide) | 2-year limited warranty |
|