We give the best SUINT3000RTXL2U price in Dubai. Also we are the top tripp lite ups system dealers and distributors in Dubai. In addition to this we are the best tripp lite SUINT3000RTXL2U suppliers in Dubai. More than this we give the best tripp lite product support services in Dubai.

Features  of SUINT3000RTXL2U

  • SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications
  • Optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation
  • Economy mode is schedulable via PowerAlert UPS management software for daily or weekly hours of operation to enable precision output during peak operating hours and high efficiency, low BTU emission operation during off-peak times
  • Maintains continuous operation through blackouts, voltage fluctuations
  • On-line, double-conversion mode provides perfectly regulated sine wave output within 2% of 200/208/220/230/240V(user selectable) with zero transfer time
  • Supports operation at 50/60Hz(auto-sensing) with the ability for full-time frequency conversion from 50 to 60Hz or 60 to 50Hz(frequency conversion de-rates UPS capacity by 20%)
  • Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types
  • Corrects line voltage conditions as low as 120V and as high as 288V to within 2% of selected nominal voltage
  • Standard internal battery set offers 15 minutes runtime at half load(1250W) and 6 minutes at full load(2500W)
  • Expandable battery runtime with optional BP72V15-2U(limit 1), BP72V28RT-3U(multi-pack compatible) and BP72V18-2US(multi-pack compatible) external battery packs
  • Intelligent battery management system extends battery life
  • Compact rackmount form factor installs using only 2 rack spaces(2U) with a depth of only 66cm / 26 inches
  • Ships with all mounting accessories for 4 post rackmount installation
  • Optional 2POSTRMKITWM enables 2 post rackmount installation
  • Optional 2-9USTAND accessory enables upright tower placement
  • Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
  • Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slot
  • HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP
  • UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment and UPS line to battery power voltage setpoints
  • Built-in Emergency Power Off(EPO) interface with cable
  • C20 inlet accepts a wide variety of user supplied input cordsets
  • C19 & C13 output receptacles
  • Includes 2 C13 to C14 and 1 C19 to C20 power cables
  • Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks(each bank has 4 C13 outlets)
  • Front panel LEDs offer current monitoring and battery charge level information
  • Network grade AC surge suppression
  • Optional PDUBHV20 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment
  • Field replaceable, hot swappable internal batteries and external battery packs.

Specifications of SUINT3000RTXL2U

OUTPUT
Output Volt Amp Capacity (VA)3000
Output kVA Capacity (kVA)3
Output Watt Capacity (Watts)2500
Output kW Capacity (kW)2.5
Output Capacity DetailsMax output is reduced to 2400W at 200V, 208V and 220V nominal settings OVERLOAD CAPACITY: Supports inverter operation. Also provides up to 100% load continuously, 120% for 30 seconds, 150% for 10 seconds and >150% for 0.1 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits). In addition to this supports SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).
Power Factor0.8
Crest Factor3:1
Nominal Output Voltage(s) Supported200V; 208V; 220V; 230V; 240V
Nominal Voltage Details230V default
Frequency Compatibility50 / 60 Hz
Frequency Compatibility DetailsOutput frequency matches input nominal on startup, defaults to 50 Hz on cold-start. More than this  frequency conversion from 60 to 50 Hz -or- 50 to 60 Hz supported. Output capacity de-rates by 20% during frequency conversion operation.
Output Voltage Regulation (Line Mode)+/- 2%
Output Voltage Regulation (Economy Line Mode)-12%, + 10%
Output Voltage Regulation (Battery Mode)+/- 2%
Output Receptacles(8) C13; (2) C19
Included Output Power CablesIncludes 2 C13 to C14 and 1 C19 to C20 power cables
Load Management ReceptaclesTwo switchable 4 C13 outlet load banks
Hot-Swap PDU optionsPDUBHV20 (2U / 6 C13, 2 C19 outlets)
Output AC Waveform (AC Mode)Sine wave
Output AC Waveform (Battery Mode)Pure Sine wave
INPUT
Rated input current (Maximum Load)15A (200V); 14.4A (208V); 13.6A (220V); 13A (230V); 12.5A (240V)
Nominal Input Voltage(s) Supported200V AC; 208V AC; 220V AC; 230V AC; 240V AC
Nominal Input Voltage Description230V factory configuration
UPS Input Connection TypeC20 inlet
UPS Input Cord Length (ft.)5 ft / 1.5m (C19 to C20)
UPS Input Cord Length (m)1.5
Input PhaseSingle-Phase
BATTERY
Full Load Runtime (min.)6 min. (2500w)
Half Load Runtime (min.)15 min. (1250w)
Expandable Battery RuntimeSupports extended runtime with optional external battery packs
External Battery Pack CompatibilityBP72V15-2U(limit 1); BP72V28RT-3U(multi-pack compatible); BP72V18-2US(multi-pack compatible)
DC System Voltage (VDC)72
Battery Recharge Rate (Included Batteries)Less than 4.8 hours from 10% to 90% (typical, full load discharge)
Internal UPS Replacement Battery CartridgeRBC96-2U
Battery AccessFront panel battery access door
Battery Replacement DescriptionHot-swappable, replaceable batteries
Expandable RuntimeYes
VOLTAGE REGULATION
Voltage Regulation DescriptionOnline, double-conversion power conditioning
Overvoltage Correction2% output voltage regulation during overvoltages to 288
Undervoltage Correction2% output voltage regulation during undervoltages to 160V
Severe Undervoltage Correction2% output voltage regulation during undervoltages to 140V (under 66% load only) or 120V (under 33% load only)
USER INTERFACE, ALERTS & CONTROLS
Switches2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel OperationPower-fail alarm can be silenced using alarm-cancel switch
Audible AlarmAudible alarm indicates power failure, low battery, overload, replace battery and EPO operation
LED Indicators14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information. More than this gives the  4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats.
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating420 joules
EMI / RFI AC Noise SuppressionYes
AC Suppression Response TimeInstantaneous
PHYSICAL
Included Mounting Accessory Description4 post installation accessories included
Installation Form Factors Supported with Optional Accessories2 post rackmount(2POSTRMKITWM); Tower(2-9USTAND)
Primary Form FactorRackmount
UPS Power Module Dimensions (hwd, cm)8.9 x 43.9 x 66
Rack Height (U Spaces)2
UPS Power Module Weight (kg)32
UPS Shipping Dimensions (hwd / cm)22.9 x 55.9 x 83.3
Shipping Weight (kg)39.9
Cooling MethodFan
UPS Housing MaterialSteel
ENVIRONMENTAL
Operating Temperature Range+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
Storage Temperature Range+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
Relative Humidity0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)1000
AC Economy Mode BTU / Hr. (Full Load)241
Battery Mode BTU / Hr. (Full Load)1500
AC Mode Efficiency Rating (100% Load)89%
AC Economy Mode Efficiency Rating (100% Load)97%
COMMUNICATIONS
Communications InterfaceUSB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
Network Monitoring Port DescriptionSupports detailed monitoring of UPS and site power conditions. Also DB9 port supports RS232 and contact closure communications
PowerAlert SoftwareIncluded
Communications CableUSB and DB9 cabling included
WatchDog CompatibilitySupports Watchdog application. In addition to this OS and hard-reboot restart options for remote applications.
LINE / BATTERY TRANSFER
Transfer TimeNo transfer time (0 ms.) in online, double-conversion mode
Low Voltage Transfer to Battery Power (Setpoint)160V (100% load), 140V (66% load), 120V (33% load)
High Voltage Transfer to Battery Power (Setpoint)288V
SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure)Cold-start operation supported
High Availability UPS FeaturesAutomatic inverter bypass; Hot swappable batteries
Green Energy-Saving FeaturesHigh efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation
CERTIFICATIONS
UPS CertificationsCE; Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to UL1778 (USA)
WARRANTY
Product Warranty Period (Worldwide)2-year limited warranty
×