Description
We give the best RG-S5750E Switch Series price in Dubai. Also we are the top Ruijie dealers in Dubai, Dubai, Sharjah, Ajman, Umm Al Quwain, Ras Al Khaimah and Fujairah
Ruijie RG-S5750E Series is a collection of new-generation Layer 3 switches offering high performance, advanced security, and multiservices. The Ruijie RG-S5750E Series provides flexible media interfaces to meet the connection needs of different media in network construction.With full Gigabit interface form, scalable high-density 10 Gigabit Ethernet ports, and 1:1 multilayer switching at full line rates, this series is ideal acting as the aggregation layer of a large network, fulfilling the demanding requirements of high bandwidth, performance and scalability, and also acting as the core layer of a medium-sized network, and access of the server cluster of a data center. The RG-S5750E Series provides hardware support for IPv4/IPv6 switching at line rates and support rich tunnel technologies for communication between IPv6 networks. We give you the best RG-S5750E Switch Series price in Dubai. Also we are the top Ruijie product dealers and distributors in Dubai. In addition to this we are the best Ruijie product partners in Dubai.
This series can be used in pure IPv4 networks, IPv6 networks, and IPv4/IPv6 dual-stack networks and meet the requirements of current and future campus network for transition from IPv4 to IPv6. The RG-S5750E Series delivers Layer 2 to 7 traffic classifications and advanced Quality of Service (QoS) policies. The series also processes different service flows based on different applications to ensure zero delay in critical data transmission.
The RG-S5750E Series offers flexible interface combination and configuration, providing 24 or 48 adaptive 10/100/1000M electrical ports as well as 4 or 8 SFP 10/100M optical ports to adapt to various network construction scenarios. The RG-S5750E Series offers outstanding performance, advanced end-to-end QoS, high flexibility, superior security settings, and policy-based network management with an unparalleled price to performance ratio to meet the enterprise customers’ needs of high speed, robust security, and intelligent network automation.
Feature highlights of RG-S5750E Series:
●Network Virtualization (VSU) Support
●Up to 4 x 10GE Ports
●Flexible Choice of Copper or Fiber Ports
●Advanced Layer 3 Routing Support
●Power Redundancy Support
<h2>Specifications:</h2>
Model | RG-S5750-24GT/8SFP-E | RG-S5750-48GT/4SFP-E | RG-S5750-24SFP/8GT-E | RG-S5750-24GT/8SFP-P | RG-S5750-48GT/4SFP-P |
Ports | 24 10/100/1000BASE-T ports | 48 10/100/1000BASE-T ports | 24 100/1000BASE-X SFP ports | 24 10/100/1000BASE-T ports (PoE+) | 48 10/100/1000BASE-T ports (PoE+) |
Expansion Slots | 2 | ||||
Modular Power Slots | N/A | N/A | 2 | 2 | 2 |
Expansion Modules | 1-port 10G SFP+ module | ||||
Management Ports | 1 console port | ||||
Switching Capacity | 256Gbps | ||||
Packet Forwarding Rate | 96Mpps | 132Mpps | 96Mpps | 96Mpps | 132Mpps |
PoE | N/A | N/A | N/A | Support | Support |
ARP Table | Up to 4,000 | ||||
MAC Address | Up to 16K | ||||
Routing Table Size | Up to 13K | ||||
IP Host Entries | Up to 13K | ||||
ACL Entries | Up to 3,000 | ||||
VLAN | 4K 802.1q VLANs, Port-based VLAN, MAC-based VLAN, Protocol-based VLAN, Private VLAN, Voice VLAN, QinQ, IP subnet-based VLAN, GVRP | ||||
QinQ | Basic QinQ, Flexible QinQ | ||||
Link Aggregation | Support LACP | ||||
Port Mirroring | Many-to-one mirroring, Flow-based mirroring, Over devices mirroring, AP-port mirroring, RSPAN | ||||
Spanning Tree Protocols | IEEE802.1d STP, IEEE802.1w RSTP, Standard 802.1s MSTP, Port fast, BPDU filter, BPDU guard, TC guard, TC protection, ROOT guard | ||||
DHCP | DHCP server, DHCP client, DHCP snooping, DHCP relay, IPv6 DHCP snooping, IPv6 DHCP client, IPv6 DHCP relay | ||||
Multiple Spanning Tree Protocol (MSTP) Instances | 64 | ||||
Maximum Aggregation Port (AP) | Up to 120 | ||||
Virtual Routing and Forwarding (VRF) Instances | 512 | ||||
VSU (Virtual Switch Unit) | Support (up to 8 stack members) | ||||
L2 Features | MAC, ARP, VLAN, Basic QinQ, Flexible QinQ, Link aggregation, Mirroring, STP, RSTP, MSTP, Broadcast storm control, IGMP v1/v2/v3 snooping, IGMP filter, IGMP fast leave, DHCP, Jumbo frame, RLDP, LLDP, REUP, G.8032 ERPS, Layer 2 protocol tunnel | ||||
Layer 3 Features | ARP proxy, Ping, Traceroute, Equal-Cost Multi-Path Routing (ECMP), URPF, Neighbor Discovery, ISATAP | ||||
Layer 3 Protocols (IPv4) | Static routing, RIP, RIPng, BGP4, BGP4+, OSPFv2/v3, IS-IS | ||||
IPv4 Features | Ping, Traceroute, URPF | ||||
IPv6 Features | ICMPv6, IPv6 Ping, IPv6 Tracert, Manually configure local address, Automatically create local address, Neighbor Discovery, 0-128 bit mask, IPv4 over IPv6 tunnel, GRE tunnel | ||||
Basic IPv6 Protocols | IPv6 addressing, Neighbor Discovery (ND), ICMPv6, IPv6 Ping and IPv6 Tracert | ||||
IPv6 Routing Protocols | Static routing, RIP, RIPng, BGP4, BGP4+, OSPFv2/v3 | ||||
IPv6 Tunnel Features | IPv4 over IPv6 tunnel, GRE tunnel | ||||
Multicast | IGMP v1/v2/v3, IGMP v1/v2/v3 snooping, IGMP proxy, IGMP filter, IGMP fast leave, Multicast routing protocols (PIM-DM, PIM-SM, PIM-SSM), MLD snooping, MLD, PIM for IPv6, MSDP, Multicast static routing | ||||
MPLS | MPLS L3 VPN | ||||
G.8032 | Support | ||||
ACL | Standard/Extended/Expert ACL, Extended MAC ACL, IPv6 ACL, ACL logging, ACL counter, ACL remark | ||||
QoS | 802.1p/DSCP traffic classification; Multiple queue scheduling mechanisms, such as SP, WRR, DRR,SP+WRR, SP+DRR; Input / output port-based speed limit; Port-based traffic recognition; Each port supports 8 queue priorities | ||||
IPv6 ACL | Support | ||||
Reliability | VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol) | VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol) | VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module | VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module | VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module |
Security | Binding of the IP address, MAC address, and port address; Binding of the IPv6, MAC address, and port address; Filter illegal MAC addresses; Port-based and MAC-based 802.1x; MAB; Portal and Portal 2.0 authentication; ARP-check; Restriction on the rate of ARP packets; Gateway anti-ARP spoofing; Broadcast suppression; Hierarchical management by administrators and password protection; RADIUS and TACACS+; AAA security authentication (IPv4/IPv6) in device login management; SSH and SSH V2.0; BPDU guard; IP source guard; CPP, NFPP; Port protection | ||||
Manageability | SNMPv1/v2c/v3, CLI (Telnet / Console), RMON (1, 2, 4, 9), SSH, Syslog/Debug, NTP, FTP, TFTP | ||||
Other Protocols | FTP, TFTP, DNS client | ||||
Dimensions | 440×260×44 | 440×300×44 | 440×300×44 | 440×400×44 | 440×420×44 |
Rack Height | 1RU | ||||
Weight | 3.9kg | 4.4kg | 4kg | 7.3kg | 8kg |
MTBF | >200K hours | >200K hours | >346K hours | >231K hours | >219K hours |
Lightning Protection | 6KV | 6KV | 6KV | 6KV | 6KV |
RPS | Support | Support | N/A | N/A | N/A |
Safety Standards | IEC 60950-1, EN 60950-1 | ||||
Emission Standards | EN 300 386, EN 55022/55032, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11 | ||||
Power Supply | Rated voltage range: 100V to 240V | Rated voltage range: 100V to 240V | AC input: | AC input: | AC input: |
Power Consumption | 43W (w/o expansion modules) | 72W (w/o expansion modules) | Dual power: Single power: | <50W (w/o both expansion modules and PD) | <80W (w/o both expansion modules and PD) |
PoE Power Consumption | N/A | N/A | N/A | 370W | 370W |
Temperature | Operating temperature: 0°C to 50°C | ||||
Storage temperature: -40°C to 70°C | |||||
Humidity | Operating humidity: 10% to 90%RH | ||||
Storage humidity: 5% to 95%RH |
<h2>Applications</h2>
Aggregation layer of a large network, core layer of medium-sized network, access of a server cluster, and full Gigabit Layer 3 access of buildings in large enterprise or campus networks
A network can be upgraded to a 10 Gigabit Ethernet uplink backbone by adding 10 Gigabit Ethernet modules so as to protect end-user investment.
Scenarios require flexible Gigabit port formation and quantity, high-performance multilayer switching and data processing.
Strong security management mechanisms provide network security defense, high-security access control, and effective network access control.
Superior management policies facilitate bandwidth management and ensure the performance of key applications such as voice/video conference, music and video streaming and Video on Demand (VoD).
10 Gigabit Ethernet Backbone Campus Network
Deployed in teaching and scientific research buildings, library and student dormitories, the Ruijie RG-S5750E Series is connected to access switches with Gigabit downlinks and to core switches with Gigabit uplinks, providing high-performance 10 Gigabit Ethernet backbone links and meeting the needs of high data traffic and large number of network nodes.
Typical 10 Gigabit Ethernet Backbone Campus Network Topology Diagram
Secure Financial LAN
Division of functional modules and powerful security protection provided by the RG-S8600, RG-S7800, and RG-S5750E Series can meet the tier 1 financial branch requirements for information systems. Establishing an integrated network security system in cooperation with data center, complete network security projects can be implemented within the tier 1 branches.
Secure Financial LAN Network Topology Diagram
Detailed Secure Financial LAN Network Topology Diagram
Core Switch for SME Network
The secure and intelligent 10 Gigabit Ethernet multilayer switch RG-S5750-24GT/8SFP-E is able to function as core switch with high backplane bandwidth and line-rate forwarding that meets application needs of primary and secondary schools, and small to medium-sized enterprises. Additionally, the Gigabit interfaces (24 Gigabit electrical ports and 8 Combo fiber ports) enable flexible connection to switches and servers.
Typical SME Network Topology Diagram
Access of Large Intranets or Campus Networks
The Ruijie RG-S5750E Series can be connected to the multiservice IPv6 core routing switch RG-S8600 Series through 10 Gigabit Ethernet or Gigabit uplinks, while the core devices are connected to one another through a 10 Gigabit Ethernet link or multiple converged Gigabit links. This connection provides seamless expansion of ports and flexible expansion of networks.
Typical Campus Network Topology Diagram