“SU6000RT4UHVG” has been added to your basket.
View basketDescription
SU6000RT4UHVHW
We give the best tripp lite SU6000RT4UHVHW price in Dubai. Also we are the top tripp lite product partners in Dubai. More than this we are the top top SU6000RT4UHVHW suppliers in Dubai.
- Tripp Lite SU6000RT4UHVHW 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system in a single 4U rack/tower compatible housing
- Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
- Detachable back panel PDU contains hardwire input and output connections, plus manual bypass switch to support hot-swappable whole UPS replacement with no interruption to connected equipment
- Hardwire input and output connections supported
- Included rail kit supports 4U 19 inch rackmount installation in 4 post racks
- Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks(1 required for SU6000RT4UHVHW)
- Optional 2-9USTAND supports upright tower placement(1 required for SU6000RT4UHVHW)
- Maximum installed rack depth of only 20.7 in. / 52.6cm inches
- Maintains full-time sine wave output within 2% of selected 200/208/220/230/240V nominal in double conversion mode
- Corrects brownouts to 156V at full load(100V at 50% load or less)
- Corrects overvoltages to 290V at full load(300V at 90% load or less)
- Supports 50/60Hz operation for worldwide frequency compatibility
- Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
- High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs
- Network-grade AC surge and noise suppression
- Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional SNMP card slot interfaces
- UPS card slot supports one card-based network interface option(part # SNMPWEBCARD) or dry-contact monitoring accessory(part # RELAYIOCARD)
- Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces
- Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification
- Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification(requires removal of USB interface module)
- HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
- Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA(Network Shutdown Agent) for larger networks and PowerAlert NMS(Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices
- Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major
- UPS functions with support for a variety of control options to support advanced UPS settings and configurations
- LED/LCD display panel rotates for viewing in rackmount or tower configurations
- Supports Emergency Power Off(EPO) via built-in interface
- Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
- BP192V12-3U external battery packs are field replaceable and hot swappable
- Intelligent battery management system with temperature-compensated charging extends battery life
- Some external battery configurations require the use of Tripp Lite’s External Battery Configuration Software(see manual)
- Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz(no de-rating)
OUTPUT |
Output Volt Amp Capacity (VA) | 6000 | Output kVA Capacity (kVA) | 6.0 | Output Watt Capacity (Watts) | 5400 | Output kW Capacity (kW) | 5.4 | Output Capacity Details | Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared | Power Factor | 0.9 | Crest Factor | 3:1 | Nominal Output Voltage(s) Supported | 200V; 208V; 220V; 230V; 240V | Nominal Voltage Details | Voltage selection via front panel LCD interface | Frequency Compatibility | 50 / 60 Hz | Frequency Compatibility Details | Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating) | Output Voltage Regulation (Line Mode) | +/- 2% | Output Voltage Regulation (Economy Line Mode) | +/- 10% | Output Voltage Regulation (Battery Mode) | +/- 2% | Output Receptacles | Hardwire | Output Receptacle Details | Hardwire input and output connections are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement | Output AC Waveform (AC Mode) | Pure Sine wave | Output AC Waveform (Battery Mode) | Pure Sine wave |
|
INPUT |
Rated input current (Maximum Load) | 31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V) | Nominal Input Voltage(s) Supported | 200V AC; 208V AC; 220V AC; 230V AC; 240V AC | UPS Input Connection Type | Hardwire | UPS Input Connection Description | Supports North American 208/240V input (L1,L2,G) or International 230/220/240V (L,N,PE) input wiring | Recommended Electrical Service | 40A (200/208v); 30A (220/230/240v) | Input Phase | Single-Phase |
|
BATTERY |
Full Load Runtime (min.) | 2 minutes (5400 watts) | Half Load Runtime (min.) | 8.5 minutes (2700 watts) | Expandable Battery Runtime | Runtime is expandable with external battery packs | External Battery Pack Compatibility | BP192V1037C-1PH; BP192V12-3U; BP192V1407C-1PH; BP192V557C-1PH; BP192V787C-1PH; BP192V5RT2U(limit 1) | DC System Voltage (VDC) | 192 | Battery Recharge Rate (Included Batteries) | 6 hours from 10% to 90% (typical, full load discharge) | Internal UPS Replacement Battery Cartridge | RBC5-192 | Battery Access | Front panel battery access door | Battery Replacement Description | Hot-swappable, user replaceable internal batteries | Expandable Runtime | Yes |
|
VOLTAGE REGULATION |
Voltage Regulation Description | Online, double-conversion power conditioning | Overvoltage Correction | Corrects overvoltages as high as 300V (<90% load) and 280V (full load) | Undervoltage Correction | Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly |
|
USER INTERFACE, ALERTS & CONTROLS |
Front Panel LCD Display | Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual) | Switches | Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads | Alarm Cancel Operation | Alarm cancel switch | Audible Alarm | Unique audible alarms for all major UPS, environmental and power conditions (see manual) | LED Indicators | 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options |
|
SURGE / NOISE SUPPRESSION |
UPS AC Suppression Response Time | Instantaneous | EMI / RFI AC Noise Suppression | Yes |
|
PHYSICAL |
Included Mounting Accessory Description | 4 post rackmount installation accessories included | Installation Form Factors Supported with Optional Accessories | 2 post rackmount(2POSTRMKITHD); Tower(2-9USTAND) | Primary Form Factor | Rackmount | UPS Power Module Dimensions (hwd, cm) | 17.4 x 44.5 x 52.6 | Rack Height (U Spaces) | 4 | Maximum Device Depth (cm) | 52.6 | UPS Power Module Weight (kg) | 52.8 | UPS Shipping Dimensions (hwd / cm) | 32.3 x 59.9 x 73.9 | Shipping Weight (kg) | 71.1 | Cooling Method | Fans | UPS Housing Material | Steel |
|
ENVIRONMENTAL |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius | Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius | Relative Humidity | 0 to 95%, non-condensing | AC Mode BTU / Hr. (Full Load) | 1767 | AC Economy Mode BTU / Hr. (Full Load) | 765 | AC Mode Efficiency Rating (100% Load) | 90% | AC Economy Mode Efficiency Rating (100% Load) | 96% | Audible Noise | 60 dBA at front side 1 meter | Operating Elevation (m) | 0-3000 m |
|
COMMUNICATIONS |
Communications Interface | USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface | Network Monitoring Port Description | Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports | PowerAlert Software | Included | Communications Cable | USB, DB9 serial and EPO cables included | WatchDog Compatibility | Yes |
|
LINE / BATTERY TRANSFER |
Transfer Time | No transfer time (0 ms.) in online, double-conversion mode | Transfer Time (Economy Mode) | 8 ms. typical power failure response in optional economy mode | Low Voltage Transfer to Battery Power (Setpoint) | 156V (full load) / 100V (50% load or less, derates linearly) | High Voltage Transfer to Battery Power (Setpoint) | 280V (full load) / 300V (90% load or less) |
|
SPECIAL FEATURES |
Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported | High Availability UPS Features | Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Manual bypass switch | Green Energy-Saving Features | High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation |
|
CERTIFICATIONS |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); CE; Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances) | UPS Certification Details | IEC 61000-4-5 1995 B Surge Immunity |
|
WARRANTY |
Product Warranty Period (Worldwide) | 2-year limited warranty | Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance |
|