SMX3000XLRT2UA price in Dubai
We are the top SMX3000XLRT2UA dealers and distributors in Dubai. More than this we are the top SMX3000XLRT2UA suppliers in Dubai. Also we are the best SMX3000XLRT2UA partners in Dubai.
- Tripp Lite SMX3000XLRT2UA line interactive 2U rack/tower UPS with 3000VA / 3kVA capacity and extended runtime options
- Line interactive UPS with Automatic Voltage Regulation(AVR) corrects brownouts and overvoltages from 158 to 278V
- C20 AC power inlet; 8 C13 and 1 C19 output receptacles, Two independently switchable output load banks
- Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages
- High 98% efficiency rating in line-power mode offers reduced power consumption and BTU emisssions
- Internal batteries offer 11.1 minutes at 50% load(1350W) and 3.9 minutes at 100% load(2700W)
- Extended runtime is available with optional external battery packs BP48V24-2U(limit 1), BP48V60RT-3U(multi-pack compatible) and BP48V27-2US(multi-pack compatible)
- External battery configurations require the use of Tripp Lite’s External Battery Configuration Software(see manual)
- Hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment
- Intelligent battery management system extends battery life
- Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed UPS and site power information
- LCD interface also supports a number of advanced user setup and operating preferences
- Ships with 4 post rackmount installation hardware; Optional 2POSTRMKITWM enables 2 post rackmount/wallmount installation; Optional 2-9USTAND enables tower placement
- Built-in USB, RS-232 and optional SNMPWEBCARD accessory monitoring options
- HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
- Included PowerAlert UPS monitoring software; Built-in Emergency Power Off(EPO) interface with cable.
OUTPUT |
Output Volt Amp Capacity (VA) | 3000 | Output kVA Capacity (kVA) | 3 | Output Watt Capacity (Watts) | 2700 | Output kW Capacity (kW) | 2.7 | Power Factor | .9 | Nominal Output Voltage(s) Supported | 220V; 230V; 240V | Nominal Voltage Details | 230v nominal inverter output voltage | Frequency Compatibility | 50 / 60 Hz | Output Voltage Regulation (Line Mode) | +6%, -15% | Output Voltage Regulation (Battery Mode) | +/-5% | Output Receptacles | (8) C13; (1) C19 | Included Output Power Cables | Set of 3 C13 to C14 power cables included | Load Management Receptacles | Two switchable single outlet C13 load banks | Output AC Waveform (AC Mode) | Pure Sine wave | Output AC Waveform (Battery Mode) | Pure Sine wave |
|
INPUT |
Rated input current (Maximum Load) | 14.1A | Nominal Input Voltage(s) Supported | 230V AC | UPS Input Connection Type | C20 inlet | UPS Input Connection Description | IEC320-C20 input connection accepts a variety of user supplied detachable C19 output cordsets to match country or site specific power sources | Input Circuit Breakers | 20A | Input Phase | Single-Phase |
|
BATTERY |
Full Load Runtime (min.) | 3.9 min. (2700w) | Half Load Runtime (min.) | 11.1 min. (1350w) | Expandable Battery Runtime | Extended runtime supported via optional external battery packs | External Battery Pack Compatibility | BP48V24-2U(limit 1); BP48V60RT-3U(multi-pack compatible); BP48V27-2US(multi-pack compatible) | DC System Voltage (VDC) | 48 | Battery Recharge Rate (Included Batteries) | Less than 5 hours from 10 to 90% (typical, full load discharge) | Internal UPS Replacement Battery Cartridge | RBC58-2U | Battery Access | Front panel battery access door | Battery Replacement Description | Hot-swappable, replaceable batteries | Expandable Runtime | Yes |
|
VOLTAGE REGULATION |
Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 158 to 278 | Overvoltage Correction | Input voltages between 244 and 278 are reduced by 12% | Undervoltage Correction | Input voltages between 206 and 183 are boosted by 12% | Severe Undervoltage Correction | Input voltages between 158 and 183 are boosted by 24% |
|
USER INTERFACE, ALERTS & CONTROLS |
Front Panel LCD Display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) | Switches | 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions | Alarm Cancel Operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available | Audible Alarm | Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
|
SURGE / NOISE SUPPRESSION |
UPS AC Suppression Joule Rating | 350 | EMI / RFI AC Noise Suppression | Yes | AC Suppression Response Time | Instantaneous |
|
PHYSICAL |
Included Mounting Accessory Description | 4 post rackmount installation hardware included | Installation Form Factors Supported with Optional Accessories | 2 post rackmount(2POSTRMKITWM); Wallmount(2POSTRMKITWM); Tower(2-9USTAND) | Primary Form Factor | Rackmount | UPS Power Module Dimensions (hwd, cm) | 8.9 x 44.4 x 49.5 | Rack Height (U Spaces) | 2 | UPS Power Module Weight (kg) | 28.5 | UPS Shipping Dimensions (hwd / cm) | 22.9 x 60.3 x 52.1 | Shipping Weight (kg) | 33 | Cooling Method | Fan | UPS Housing Material | Steel |
|
ENVIRONMENTAL |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius | Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius | Relative Humidity | 0 to 95%, non-condensing | AC Mode BTU / Hr. (Full Load) | 158 | AC Mode Efficiency Rating (100% Load) | 98% |
|
COMMUNICATIONS |
Communications Interface | USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface | Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions | PowerAlert Software | Included | Communications Cable | USB, DB9 and EPO cabling included | WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
LINE / BATTERY TRANSFER |
Transfer Time | 6 milliseconds (AC to battery mode), 1 millisecond (Battery to AC mode) | Low Voltage Transfer to Battery Power (Setpoint) | 158 | High Voltage Transfer to Battery Power (Setpoint) | 278 |
|
SPECIAL FEATURES |
Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported | High Availability UPS Features | Hot swappable batteries | Green Energy-Saving Features | Greater than 95% efficiency – GREEN UPS; Individually controllable load banks; Schedulable daily hours of economy mode operation |
|
CERTIFICATIONS |
UPS Certifications | CE; ROHS (Restriction of Hazardous Substances) | UPS Certification Details | IEC 62040-1, IEC 62040-2 Class A EMI, GOST |
|
WARRANTY |
Product Warranty Period (Worldwide) | 2-year limited warranty |
|